How Accurate Are Non-Contact Thermometers? (2024)

How Accurate Are Non-Contact Thermometers? (1)Temporal artery thermometers and non-contact thermometers are both used to measure body temperature, however they work in different ways.

A temporal artery thermometer uses infrared technology to measure the temperature of the temporal artery, which is located on the forehead. In comparison, non-contact thermometers use infrared technology to measure the temperature of the surface of the skin, typically used by scanning the forehead.

Though both touchless thermometer options and temporal artery methods are non-invasive, the former often yields less accuracy by only gauging skin temperature.

Why are Non-Contact Thermometers Highly Inaccurate?

Exploring how accurate are no-touch thermometers: they often fail in detecting fevers accurately due to surface skin measurements. Here is why:

Reason #1 It Measures Skin Surface

One reason no-touch thermometer readings may not be accurate is that they assess skin temperature, not the body's core temperature. As a result, the thermometer may not accurately reflect the individual's true temperature if they have a fever.

Reason #2: The Scan Distance and Positioning

No-touch thermometer accuracy is compromised by improper positioning and scan distance, leading to potential inaccuracies. To get the most accurate reading, no-touch thermometers must be positioned at the correct distance from the skin surface. However, the misuse of this thermometer at an incorrect distance from the skin can often cause inaccurate readings.

Reason #3: Environment Temperature

Another reason affecting non-contact thermometer accuracy is the environment temperature where the measurement is taken. The environmental temperature can also impact the accuracy of the non-contact thermometer, which is sensitive to ambient temperature. This sensitivity means that if the temperature in the room is different from the person being measured, the reading of the thermometer may be inaccurate.

Studies

The accuracy of no-touch thermometers as claimed by manufacturers often pertains to lab settings, not real-world fever testing. Laboratory accuracy tests do not include important physiological effects which vary from person to person, and setting to setting, rendering no-touch thermometers unreliable, regardless of their laboratory accuracy.

For no-touch devices, these physiological effects can overwhelm the normal laboratory accuracy of the device, to the point that its actual error is 2 deg C rather than 0.2 deg C.

Estimated standard deviation oftemperatureuncertainty

PhysiologicalVariable

Est. Range

No-Touch Thermometry

TA Thermometry

Skinemissivity

0.97±0.02

0.31°C

0.03°C

Skinambient temperature

±5°C

0.58°C

0.06°C

Variable perfusion on face

±1°C

0.58°C

0.06°C

Perspirationon theface

±1°C

0.58°C

0.06°C

95%confidenceintervaloferrors duetoidentifiableskin physiologicalvariables

2.09°C

0.21°C

This discrepancy in accuracy was clearly observed during the SARS epidemic in 2003. Exergen, recognized as experts in this field, was asked to provide the underlying science in a study regarding this accuracy discrepancy at a Symposium in 2004, which was subsequently published. The chart above is from that published study, and shows that the errors due to physiological effects is +/- 2.09 deg C.,compared to the light contact method of temporal artery (TA) scanning error of +/- 0.21 deg C. The TA thermometer was specifically designed to overcome these physiological barriers to obtaining accurate readings, and were awarded numerous patents on the design. (Pompei and Pompei 2004). Subsequent studies confirmed the Pompei findings of 2004.

In 2009, Bitar et al. reviewed 6 studies of fever screening with non-contact infrared thermometry (NCIT) devices, such as thermometer guns and thermal imagers. Across the reviewed studies, the sensitivity of NCIT ranged from 4% to 90% and its specificity ranged from 75% to 100%. In other words, NCIT detected fever in from 4% to 90% of the people with fevers, and NCIT did not detect fever in from 75% to 100% of people who lacked fever. The extremely wide range of reported sensitivities (4% to 90%) suggests generally poor usefulness of the NCIT methods, both because values at the low end of the range are unacceptably poor (4% of fevers detected), and because it is difficult to recommend a technology for which the user cannot tell if they will receive good (90%) or disastrous (4%) performance. https://www.eurosurveillance.org/content/10.2807/ese.14.06.19115-en

In 2019, Mouchtouri et al. reviewed the real-world efficacy of fever screening at airports and borders, and found that almost no disease cases had been caught across several nations and pandemics. The screenings were primarily performed with thermometer guns and thermal imagers. https://www.mdpi.com/1660-4601/16/23/4638

It is now common knowledge in the professional medical community that non-contact thermometers are too inaccurate to use as a reliable screening device for fever, and are used largely for theater effects. An August 13, 2020 article in Forbes magazine quotes Dr. Anthony Fauci, director of the National Institute for Allergy and Infectious Diseases, as saying, when referencing infrared thermometers that take a person’s body temperature by aiming the device at their forehead, “We have found at the [National Institutes of Health] that it is much, much better to just question people when they come in and save the time, because the temperatures are notoriously inaccurate many times.”

Without peer-reviewed published clinical studies, non-contact thermometers commonly available cannot be relied upon for medical accuracy in fever detection.

Accuracy of Exergen Temporal Artery Thermometers

With more than 100 published peer-reviewed clinical studies attesting to the accuracy on all ages from newborns to geriatrics, in all settings where fever detection is needed, the Exergen temporal artery thermometer is by far the most proven accurate, compared to thermometers which have no or very few clinical studies. Learn more about the accuracy of temporal thermometers.

How Accurate Are Non-Contact Thermometers? (2024)
Top Articles
Latest Posts
Article information

Author: Fredrick Kertzmann

Last Updated:

Views: 6439

Rating: 4.6 / 5 (66 voted)

Reviews: 89% of readers found this page helpful

Author information

Name: Fredrick Kertzmann

Birthday: 2000-04-29

Address: Apt. 203 613 Huels Gateway, Ralphtown, LA 40204

Phone: +2135150832870

Job: Regional Design Producer

Hobby: Nordic skating, Lacemaking, Mountain biking, Rowing, Gardening, Water sports, role-playing games

Introduction: My name is Fredrick Kertzmann, I am a gleaming, encouraging, inexpensive, thankful, tender, quaint, precious person who loves writing and wants to share my knowledge and understanding with you.