Part 3: Columns

This article is the third in a series (STRUCTURE: Part 1 – June 2019, Part 2 – July 2019) on recommended reinforcement details for cast-in-place concrete construction.

Detailing Longitudinal Reinforcement

Once the size of the cross-section and the required area of longitudinal reinforcement have been determined for a reinforced concrete column based on strength requirements, the size and number of longitudinal reinforcing bars must be chosen to 1) provide an area of reinforcement equal to or greater than the amount that is required, and 2) satisfy the minimum and maximum spacing requirements in ACI 318-14, Building Code Requirements for Structural Concrete and Commentary. Columns that have longitudinal reinforcement ratios in the range of 1 to 2% are usually the most economical because concrete resists axial compression forces more cost-effectively than reinforcing steel. It is usually more economical to use larger column sizes with less longitudinal reinforcement.

Table 1. Minimum number of longitudinal bars in a column.

The minimum number of longitudinal bars in a column based on the type of transverse reinforcement is given in ACI 318 Section 10.7.3.1 (Table 1). Where longitudinal bars are in a circular arrangement, the orientation of the bars has an impact on the moment strength of a column where less than 8 longitudinal bars are provided; this must be considered in the design.

Minimum clear spacing between the longitudinal bars is given in ACI 318 Section 25.2 (Figure 1). In the figure, db is the diameter of the longitudinal bars and dagg is the nominal maximum size of coarse aggregate in the mix. The longitudinal bars must be spaced far enough apart so that concrete can easily flow between the bars. Minimum bar spacing is especially critical at splice locations.

Table 2. Minimum face dimension (inches) of rectangular tied columns with normal lap splices.

To facilitate the selection of the longitudinal bars, Table 2 contains the minimum face dimension of rectangular tied columns with normal lap splices based on the minimum spacing requirements assuming 1.5-inch clear cover to #4 ties. The column face dimensions have been rounded to the nearest inch. Similar tables can be created for other tie bar sizes and circular longitudinal bar arrangements.

For columns in ordinary moment frames in buildings assigned to Seismic Design Category (SDC) A or B, or in intermediate moment frames in buildings assigned to SDC C, lap splices of the longitudinal bars are permitted to occur immediately above the top of the slab, which is the preferred location for ease of construction (Figure 2). The type of lap splice that must be used depends on the stress in the longitudinal bars due to the factored load combinations (see ACI 318 Section 10.7.5.2).

For columns that are part of special moment frames in buildings assigned to SDC D, E, or F, lap splices must be tension lap splices and located within the center half of the column length. These lap splices also must be located away from the ends of the column where spalling of the concrete shell surrounding the transverse reinforcement is likely to occur due to a seismic event (ACI 318 Section 18.7.4.3).

Detailing the Transverse Reinforcement

Requirements for columns with tie reinforcement are given in ACI 318 Sections 10.7.6 and 25.7.2, and standard hook dimensions for ties are given in ACI Section 25.3.2. Tie spacing requirements for reinforced concrete columns in buildings assigned to SDC A and B are given in Figure 3. The clear spacing between ties must be at least (4/3)dagg. Depending on the shear strength requirements, the required tie spacing may be less than that in the figure.

Figure 3. Tie requirements for reinforced concrete columns in buildings assigned to SDC A and B.

The provisions of ACI 318 Section 25.7.2.3, which pertain to rectilinear tie configurations and the maximum clear spacing permitted between laterally supported longitudinal bars, are illustrated in Figure 4 and ACI 318 Figure R25.7.2.3a. Lateral support must be provided for longitudinal bars that have a clear spacing greater than 6 inches from a laterally supported bar on each side along the tie.

Figure 4. Lateral support requirements for longitudinal bars in tied columns.

There are numerous ways to arrange ties in a column, and some arrangements are preferred more than others. Consider the arrangements in Figure 5. The arrangements in Figures 5a and 5b are preferred over the arrangement in Figure 5c because 1) the outer confinement tie acts as a template for the ironworker to place the longitudinal bars; 2) it is easier to maintain the required concrete cover using side-form spacers; 3) it is more efficient at preventing displacement of the longitudinal bars while the column cage is being moved into place by the crane; and (4) the tasks that are needed to be completed by the ironworker are simplified, which translates to increased productivity.

Figure 5. Column tie arrangements; a) With outer confinement tie and inner closed tie, b) With outer confinement tie and crosstie, c) With paired overlapping ties.

Transverse reinforcement requirements in columns that are part of intermediate and special moment frames are given in ACI 318 Sections 18.4.3 and 18.7, respectively.

Requirements for columns with spiral reinforcement are given in ACI 318 Sections 10.7.6 and 25.7.3. Standard spiral sizes are #3 to #5, and the clear spacing between consecutive turns on a spiral must not exceed 3 inches or be less than the greater of 1 inch or (4/3)dagg. Recommended standard spirals for circular columns with Grade 60 reinforcement and various concrete compressive strengths are given in Table 3.

Table 3. Recommended standard spirals for circular columns.

Additional recommendations and guidelines for detailing reinforced concrete columns in buildings assigned to any SDC can be found in the CRSI publications Design Guide for Economical Reinforced Concrete Structures and Design Guide for Reinforced Concrete Columns.■

References

ACI (American Concrete Institute). 2014. Building Code Requirements for Structural Concrete and Commentary. ACI 318-14, Farmington Hills, Michigan.

CRSI (Concrete Reinforcing Steel Institute). 2016. Design Guide for Economical Reinforced Concrete Structures. Schaumburg, IL.

CRSI (Concrete Reinforcing Steel Institute). 2018. Design Guide for Reinforced Concrete Columns. Schaumburg, IL.

STRUCTURE magazine |   Recommended Details for Reinforced Concrete Construction (2024)

FAQs

What are the basic requirements of reinforced concrete structure? ›

Reinforced concrete design involves the use of steel reinforcement to strengthen and reinforce the concrete. The basic principles include providing adequate structural support; ensuring proper connections between members; controlling crack widths; and designing for durability, fire resistance, and seismic resistance.

What is the minimum clear cover for ACI 318? ›

ACI 318 recommends a minimum of 1.5 inches of cover for most structures, and increases it to 2 inches of cover for protection from deicing salts. ACI 357 recommends 2.5 inches of mini- mum cover in marine environments. Larger aggregates require more cover.

How do you detail reinforced concrete? ›

Detailing is done in two stages. The first is the communication of the design from the licensed design professional to the reinforcement fabricator on structural drawings. The second is the communication of the field assembly from the reinforcement fabricator to the contractor on placement drawings.

What is the overview of reinforced concrete structure? ›

The reinforced concrete structure used most widely in engineering practice is mainly composed of one-dimensional members, of which the internal forces on the section are singly axial force, bending moment, shear force, or torque and the composition of them.

What is the minimum cover for reinforced concrete? ›

The minimum required cover thickness of the foundation reinforcement is around 40 mm for foundation lying on a lean concrete layer and around 70 mm for foundation in direct contact with the soil.

What is the minimum recommended grade for reinforced concrete? ›

The most commonly used minimum grade for general construction purposes is M20. In the Indian context, the "M" stands for Mix design, and the number after "M" represents the characteristic compressive strength of the concrete mix in megapascals (MPa) at 28 days.

What is the minimum rebar spacing for ACI? ›

The minimum spacing is the maximum of 1 in, a bar diameter, or 1.33 times the maximum aggregate size. sections with the web width (bw) in place of b. The total compression that balances the tension is now: T = Cc + Cs.

What is the minimum edge distance for ACI 318? ›

5.8.

ACI 318 requires that cast-in headed fasteners, which will be torqued, have minimum edge distances of 6d.

What is the difference between ACI 301 and ACI 318? ›

While ACI 318 (the code) presents minimum requirements related to construction methods and materials relative to public safety, ACI 301 presents more than the minimum requirements on construction methods and materials relative to the actual concrete construction.

How thick should reinforced concrete be? ›

In most cases, you'll want your patio to be 4 inches thick, although you should add reinforcement and increase the thickness up to around 8 inches if you want it to support heavier loads and resist cracking more readily. Although thicker slabs will cost more, you'll start seeing diminishing returns at around 6 inches.

Do you need rebar for a 6 inch slab? ›

Rebar is recommended for concrete slabs that measure 5 – 6 inches in depth, which is about the depth of slab you'd need if you plan to drive on it or use it to house heavy machinery (like a large RV, for example).

What is the shift rule in concrete? ›

Longitudinal reinforcement should be extended beyond the point at which it is no longer required for flexural strength by a distal al which may calculated or conservatively be taken as al = 1.125d (this is known as the 'shift rule').

What is the difference between concrete and reinforced concrete? ›

Reinforced concrete has steel embedded within it while unreinforced concrete dow not. The reinforcement is used to carry tensile loads, Unreinforced concrete is only good for compression loads.

What are the three methods of design of reinforced concrete structures? ›

Reinforced Concrete Design Method
  • The working stress method (WSM)
  • The ultimate load method (ULM)
  • The limit state method (LSM)

How long does reinforced concrete last? ›

Early 20th-century engineers thought reinforced concrete structures would last a very long time – perhaps 1,000 years. In reality, their life span is more like 50-100 years, and sometimes less.

What are the basics of reinforced cement concrete? ›

reinforced concrete, concrete in which steel is embedded in such a manner that the two materials act together in resisting forces. The reinforcing steel—rods, bars, or mesh—absorbs the tensile, shear, and sometimes the compressive stresses in a concrete structure.

What are the basic structural requirements? ›

To perform its function of supporting a building in response to whatever loads may be applied to it, a structure must possess four properties: it must be capable of achieving a state of equilibrium, it must be stable, it must have adequate strength and it must have adequate rigidity.

What are the general requirements of concrete? ›

The first requirement for good concrete is to use a cement type suitable for the work at hand and have a satisfactory supply of sand, coarse aggregate, and water. Everything else being equal, the mix with the best graded, strongest, best shaped, and cleanest aggregate makes the strongest and most durable concrete.

What are the basic requirements of structural design? ›

Several key elements are considered in structural design, including:
  • Load-bearing capacity: The ability of a structure to support loads and forces.
  • Stability: The resistance of a structure to overturning, sliding, or collapsing.
  • Strength: The capacity of a structure to resist applied forces without failure.
Feb 26, 2024

Top Articles
Latest Posts
Article information

Author: Zonia Mosciski DO

Last Updated:

Views: 6087

Rating: 4 / 5 (51 voted)

Reviews: 90% of readers found this page helpful

Author information

Name: Zonia Mosciski DO

Birthday: 1996-05-16

Address: Suite 228 919 Deana Ford, Lake Meridithberg, NE 60017-4257

Phone: +2613987384138

Job: Chief Retail Officer

Hobby: Tai chi, Dowsing, Poi, Letterboxing, Watching movies, Video gaming, Singing

Introduction: My name is Zonia Mosciski DO, I am a enchanting, joyous, lovely, successful, hilarious, tender, outstanding person who loves writing and wants to share my knowledge and understanding with you.